The Academy of medical Sciences of the USSR there is a laboratory of experimental physiology in the revitalization of the body. This laboratory is engaged in studying of laws of descent and restore the vital functions of the organism in the experiment on animals, as well as treatment of patients in the clinic.
In this lab, which in 1960 celebrated the twenty-fifth anniversary of its existence, was created a complex method of recovery to be successfully applied in recent years in the clinic. Using this technique have been clarified many important issues, help deepen imagine the decline processes and restore the life of the organism.
Developed by the laboratory methodology consists of four main parts:
1. Rhythmic pumping oxygenated blood in the artery centripetal, that is, towards the heart.
2. Artificial respiration with the aid of machines, duwayma air into his lungs.
3. Electrical defibrillation heart.
4. Heart massage.
For blood pressure blood apply normal vial of conserved blood, pre-saturated with oxygen. In addition, for better blood supply to the heart muscle add 10 ml of 40% glucose solution and 0.5-1 ml of adrenaline - for stimulation of cardiac contractions. To the lower end of ampoules join the regular system for blood transfusion, and to top - rubber balloon to create pressure in the ampoule and a pressure gauge to monitor this pressure.
To be injected blood under strictly dosed pressure you in any artery, but it is better to use peripheral artery (shoulder, radiation). As already indicated, the needle is injected into an artery in the direction of the heart that the blood more quickly got into the blood to vital organs. As soon as a first heart reduction - this can be judged by a heart - to enter the blood in the artery stop and begin to pour it into the vein (do this in order to compensate for blood loss).
What is the mechanism of action of blood, entered into an artery? After a few seconds it goes to the heart vessels and ensures the supply of oxygen and nutrients. At the same time the blood, put under pressure in the artery, irritates nerve endings in the walls of blood vessels and cardiac muscle, increases their tone, stimulates contractions of the heart. All this contributes to the restoration of cardiac activity.
In the early stages of dying, it ceases to breathe by himself, but retained the heart activity, for the recovery of a sick quite often use manual artificial respiration method Sylvester or Scheffer.
But if he not only stopped breathing and cardiac activity and came clinical death, manual artificial respiration, which produces only a small pulmonary ventilation, less effective.
In these cases, using special devices, duwayma air into his lungs. Air is injected through a mask that is worn on the face, or through a special rubber tube (incubator) - it is inserted through the mouth into the trachea. With this method in the lungs of more air than with manual artificial breath. This provides a better gas exchange in the lungs. In addition, smoothing pulmonary alveoli irritating vagal nerve endings. The resulting impulses are transmitted to the respiratory center, located in the medulla, contribute to the restoration of its activities. Based on this principle the use of simple devices built on the blacksmith's fur, and more difficult, as for example the Soviet apparatus DP-2. He is driven by the energy of compressed oxygen in an oxygen cylinder. The air is enriched with oxygen is pumped into the lungs to create in them a certain pressure is then automatically is drawn from the lungs to create negative pressure. Thus, the pressure, created in the lungs, regulates automatic switching of the unit to inhale or exhale. Using this device you can also provide the patient with oxygen and suck the fluid and mucus from the respiratory tract.
When the lung tissue damage and pulmonary edema, such as drowning, different intoxications and in some other cases the phone, vdavali the air in the lungs, can not be applied. Then produce artificial respiration apparatus type pneumatic cuff, for example AM-1. The inflate and its suction occurs due to compression and tension rubber bellows, which results in the progressive movement through the reduction gear single-phase asynchronous electric motor of alternating current. In the absence of the power grid, the machine can operate manually.